USAfixTM - Repair Guide (RG) - Master Email RG
- Replace the leaking hose between the tank and the solution filter
 Level of Difficulty - MEDIUM  Estimated Completion Time - 30 minutes
TASKI - SWINGO 350B

Tools Required
Tool 
Pliers-needle nose
Torx T30

Parts Required
PartDescriptionPriceAvailablePurchase
192-9207 Hose with protection (sold by the inch) $22.22 Back Order Qty:


Step Procedure & Parts & Tools
1 LIFT THE RECOVERY TANK FROM THE MACHINE AND CARRY TO DRAIN TO EMPTY. PUSH THE MACHINE OVER A DRAIN AND REMOVE THE YELLOW SOLUTION FILTER CAP TO DRAIN THE SOLUTION TANK.

2 RAISE THE TANK COVER UP UNTIL IT POPS OFF MACHINE.

3 LOCATE THE 2 HOSES COMING UP THRU THE SOLUTION TANK. PULL THE HOSE CUFFS OFF HOSES.

4 REMOVE THE 4 BOLTS HOLDING THE BATTERY COVER.
Torx T30

5 SLIDE BOTH BATTERIES FROM THE BATTERY COMPARTMENT. NO NEED TO DISCONNECT THE CABLES.

6 REMOVE THE 2 BOLTS IN THE BATTERY COMPARTMENT.
Torx T30

7 LOOSEN THE BOLT ON THE FRONT OF THE SOLUTION TANK.
Torx T30

8 REMOVE THE 2 SOLUTION TANK BOLTS ON EACH SIDE OF THE TANK.
Torx T30

9 RAISE THE SOLUTION TANK UP.

10 REMOVE THE HOSE AND HOSE CLAMP AT THE TANK.
Pliers-needle nose

11 REMOVE THE HOSE AND HOSE CLAMP AT THE SOLUTION FILTER.
Pliers-needle nose

12 REVERSE STEPS 1 THRU 11 TO REPLACE THE HOSE AND REASSEMBLE THE MACHINE. HOSE SOLD BY THE INCH.

PartDescriptionPriceQty
192-9207 Hose with protection (sold by the inch) $22.22 Qty: